| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | FBC |
| Model Number : | YT |
| Certification : | UN38.3,MSDS |
| Price : | 1500~2500 Dollar/item |
| Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability : | 1000/item/day |
| Delivery Time : | 14~28work days |
Solar inverter energy storage battery all-in-one
The integrated design of inverter and battery reduces the use of
space and installation time
A-class quality battery, built-in BMS, LCD display, safe, simple
operation, can increase WIFI APP remote control
Professional technical team and sales team to ensure pre-sales and
after-sales service
10 years of offline production experience to meet all kinds of
OEM/ODM customization services

| Grid module | |
| Rated input voltage | 220/230Vac |
| Input voltage range | (170Vac~280Vac) ±2% (90Vac-280Vac)±2% |
| frequency | 50Hz/ 60Hz (Automatically detects) |
| Frequency range | 47±0.3Hz ~ 55±0.3Hz (50Hz); 57±0.3Hz ~ 65±0.3Hz (60Hz); |
| Overload/short circuit protection | disconnect |
| efficiency | >95% |
| Transfer time (bypass and inverter) | 10ms (Typical value) |
| AC backfill protection | YES |
| Maximum bypass overload current | 40A |
| Inverter module | |
| Output voltage waveform | pure sine wave |
| Rated output power | 5000 (VA) |
| Power Factor | 1 |
| Rated output voltage | 230Vac |
| Output voltage error | ±5% |
| Output frequency range | 50Hz ± 0.3Hz 60Hz ± 0.3Hz |
| Efficiency | >92% |
| Overload protection | (102%< load <125%) ± 10%: report an error and shut down the output after 5 minutes; (125%< load <150%) ± 10%: report an error and shut down the output after 10 seconds; Load >150% ±10%: report an error and shut down the output after 5 seconds; |
| peak power | 10000VA |
| On-load motor capacity | 4HP |
| Battery voltage range | 40.0Vdc~60Vdc ± 0.6Vdc (Under-voltage alarm / shutdown voltage / the over-voltage alarm/over-voltagerenew…LCD Screen can be set) |
| Power saving mode | load≤50W |
| Grid charging | |
| maximum-charging current (can be set) | 60A |
| Charging current error | ± 5Adc |
| charging voltage range | 40 – 58Vdc |
| Short circuit protection | Circuit breakers and blown fuses |
| Circuit Breaker Specifications | 40A |
| Overcharge protection | Alarm and turn off charging after 1 minute |
| Solar change | |
| Maximum PV ,Open circuit voltage | 145Vdc |
| PV Operating voltage range | 60-145Vdc |
| MPPT voltage range | 60-115Vdc |
| Battery voltage range | 40-60Vdc |
| Maximum input power | 4400W |
| Solar charging current range (can be set) | 0-80A |
| Charging short circuit protection | blow fuse |
| Wiring protection | reverse polarity protection |
| Maximum Hybrid Charge Current( PV+AC) | |
| Maximum hybrid charge Current (can be set) | 0-140A |
| Other Specification | |
| Range of working temperature range | -15°C to 55°C |
| Storage temperature range | -25°C ~ 60°C |
| Humidity range | 5% to 95% (Three anti-paint protection) |
| Noise | ≤60dB |
| Heat dissipation | Forced air cooling, adjustable wind speed |
| Communication interface | USB/RS485(WiFi/GPRS)/Dry Node Control |


|